| Sign In | Join Free | My infospaceinc.com |
|
Reverse Leakage Current (Ir) : 5uA
Non-Repetitive Peak Forward Surge Current : 30A
Operating Junction Temperature Range : -40℃~+150℃
Voltage - DC Reverse (Vr) (Max) : 1.6kV
Voltage - Forward(Vf@If) : 2.2V@1.0A
Current - Rectified : 1A
Description : Diode 1600V 1A Through Hole DO-41
Mfr. Part # : HVR116
Model Number : HVR116
Package : DO-41
The HVR112 - HVR120 series are high voltage rectifier diodes designed for applications requiring high current and surge current capabilities, high reliability, low reverse current, and low forward voltage drop. These diodes are Pb/RoHS free and housed in a DO-41 molded plastic case.
| Symbol | HVR112 | HVR114 | HVR116 | HVR118 | HVR120 | Unit |
|---|---|---|---|---|---|---|
| Maximum Repetitive Peak Reverse Voltage | 1200 | 1400 | 1600 | 1800 | 2000 | V |
| Maximum RMS Voltage | 840 | 980 | 1120 | 1260 | 1400 | V |
| Maximum DC Blocking Voltage | 1200 | 1400 | 1600 | 1800 | 2000 | V |
| Maximum Average Forward Current (Ta = 75C) | 1.0 | A | ||||
| Maximum Peak Forward Surge Current (8.3ms Single half sine wave) | 30 | A | ||||
| Maximum Peak Forward Voltage (at IF = 1.0 A) | 2.2 | V | ||||
| Maximum DC Reverse Current (Ta = 25C at Rated DC Blocking Voltage) | 5.0 | A | ||||
| Maximum DC Reverse Current (Ta = 100C at Rated DC Blocking Voltage) | 100 | A | ||||
| Typical Junction Capacitance (Note 1) | 36 | pF | ||||
| Typical Thermal Resistance (Note 2) | 26 | C/W | ||||
| Junction Temperature Range | - 40 to + 150 | C | ||||
| Storage Temperature Range | - 40 to + 150 | C | ||||
Notes:
(1) Measured at 1.0 MHz and applied reverse voltage of 4.0VDC
(2) Thermal resistance from Junction to Ambient at 0.375" (9.5mm) Lead Lengths, P.C. Board Mounted.
|
|
High voltage rectifier diode EIC HVR116 with 1600V peak reverse voltage and low forward voltage drop Images |